8.4.2.3 Region Exiting

Region exiting is to make sure that any person or object won't exit the area that is being monitored. Any exit of people or objects will trigger an alarm.

Settings steps are shown as follows:

[Detection Settings]

Note: General Settings will take effect in all detection regions/lines!

Step1: Selected effective region including Normal and Advanced;

Normal mode is effective for all detection areas;

Advanced methods will work in specific fields of view and require setting a preset.

Step2: Selected detection region and enable region exiting detection;

Step3: Choose detection object. Check Human or Vehicle attribute, and the camera will alarm once detecting people or vehicle and triggering related events.

[General Settings]

Step4: Set detecting sensitivity and object size limits;

Table 1. Description of the buttons
Parameters Function Introduction
Sensitivity Level 1~10 are available, the default level is 5. The higher the sensitivity, the easier it is for moving objects to be recorded in the results.

Trigger Mode

Set the desired mode of the trigger logic including General Mode and Bottom Mode.

General Mode: The alarm is triggered when the object's body roughly enters the detection area.

Bottom Mode: the alarm will be triggered as soon as the bottom of the object enters the detection area. Suitable for scenarios that require sensitivity to intrusion status/bottom detection preference.

Min. Size

Draw the screen to set the minimum size of the detected object. When the object is smaller than this size, it will not be detected. The default minimum size is 3*3.

Max. Size

Draw the screen to set the maximum size of the detected object. When the object is larger than this size, it will not be detected. The default maximum size is 320*240.

[Schedule Settings]

Step5: Set detection schedule;



Note: This part is the same as the regular schedule settings. You can refer to 8.4.2.2 Region Entrance.

[Alarm Action]

Step6: Set alarm action;



Note: This part is the same as the regular alarm settings. You can refer to 8.4.2.1 Intrusion Detection.